Compressors Air Dryers (Heatless)

• Extensive Mimic display  
• Energy Saving Purge Economiser 
• Filters Autodrain Valves  
• 35 Sales & Service outless across the World

Highlights

Purge Economiser :
By setting a switch in the controller at a percentage of maximum flow, the controller will close the purge valve when sufficient Purge air has been used. This reduces purge loss according to air usage. The purge loss, Which is 14% normally reduces to as low as 5.6%.

No pressure spike : During changeovers ensures long desiccant part of the Dryer, and not as an accessory.

Pre/Oil Filters are fitted with automatic Drain Valve as an integral part of the Dryer, and not as an accessory.
Selection Example

Requirement :
Flow Volume 
: 175 cfm
Working Pressure 
: 6 kg/cm2
Inlet air Temperature
: 45%c
Referring the Graphs
: Factor (T) = 0.9
  Factor (P) = 0.88
Dryer capacity required
:Flow volume
       175
 
___________________________________
 = 220.9 cfm
Factor (T) x Factor (P)    0.9x 0.88  

Choose the nearest higher model i.e, Model DP 384

Specification

Model
Inlet Flow cfm
End Connection
Dimensions (mm)
Weight Kg
Hight
Width
depth
DP-192
114
1" BSP
2000
 750
650
380
DP-288
172
1" BSP
2050
 750
650
440
DP-384
229
    1 1/2 BSP
2100
 750
650
550
DP-480
286
2" NB
1640
1200
1300
620
DP-576
343
2" NB
1975
1200
1300
700
DP-768
458
2" NB
1860
1200
1300
850
DP-960
572
    2 1/2 NB
2200
1200
1300
950
 DP-1440
860
3" NB
1925
1500
1500
  1265
 DP-1920
  1144
3" NB
2350
1500
1500
  1575
 
• Operation voltage - 230 V AC 50 Hz LPH.
• For any other capacity contact factory.
• Specifications are subject to change without notification.

   
   
   
Refrigeration Compressed Air Dryer
Coldspell
• Helium Tested Stainless plate heat exchanger
• Microprocessor Controller
• Maintains Constant Dewpoint
• Large condensor for high ambient temperatures
• 45 Sales & Services outlets across the Nation.

Principle of Operation - Coldspell
Warm compressed air enters the air / Air Heat Exchanger where it is precooled by outgoing cold dry air. Pre-cooling makes it possible to use a smaller (More Economical) refrigeration Unit. The pre-cooled air enters the air to Freon Heat Exchanger where it is cooled down to +3oC. At this temperature, water condenses into liquid droplets, Which are removed from the air stream by a very efficient Demister and automatically discharged to drain by a Trident Automatic Drain Valve. The Cold dry compressed air passes back through the secondary side of the Air to Air Heat Exchanger where it is reheated by the incoming warm air. Reheating the outgoing compressed air increases the volume of the air enabling it to do more work and it also prevents downstream pipe sweating. Trident Heat Exchanger has no extended surface or Sharp corners that collect dust, dirt or oil residue. Any dust, dirt or out will be washed from the air system along with the condensed moisture at the De-mister.